Your order will be processed in GBP.
[switch currency to EUR]

Order Request an official quote (RFQ)
Order Code, Price (EUR/GBP) Probes per set
PPP-EFM-10 10 pcs
€ 461.00 £ 406.00 add to shopping cart
PPP-EFM-20 20 pcs
€ 823.00 £ 724.00 add to shopping cart
PPP-EFM-50 50 pcs
€ 1814.00 £ 1596.00 add to shopping cart
PPP-EFM-W 380 pcs
€ 9525.00 £ 8382.00 add to shopping cart

Product Availability: 5 - 10 working days


AFM Probe type:

PPP-EFM

Manufacturer: NANOSENSORS
Product Description:

The PointProbe®Plus (PPP) combines the well-known features of the proven PointProbe® series such as high application versatility and compatibility with most commercial SPMs with a more reproducible tip radius as well as a more defined tip shape. The minimized variation in tip shape provides more reproducible images.

The PPP-EFM probe is offered for electrostatic force microscopy. An overall metallic coating (PtIr5) on both sides of the cantilever increasing the electrical conductivity of the tip. The force constant of this type is specially tailored for the electrostatic force microscopy yielding very high force sensitivity while simultaneously enabling tapping mode and lift mode operation.

The probe offers unique features:

  • metallic conductivity of the tip
  • high mechanical Q-factor for high sensitivity
  • precise alignment of the cantilever position (within +/- 2 µm) when used with the Alignment Chip
  • compatible with PointProbe® Plus XY-Alignment Series
Please note:
  • Wear at the tip can occur if operating in contact-, friction- or force modulation mode.
  • Although this is possible, it is not recommended to use PtIr5 coated tips for electrical contacting in applications where it is necessary to conduct high current. The very thin layer of PtIr5 is unable to support much current.

 

Application Modes:
AFM Probe Specifications:
AFM Tips:
shape tip height tip set back tip radius full cone angle half cone angle
Standard 0 µm (10 - 15 µm)* 10 - 15 µm* 0 µm ( 10 - 15 µm)* < 25 nm

AFM Cantilever(s):
cant. shape length width thickness force const. res. freq. probe base
Beam 225 µm (215 - 235 µm)* 28 µm (20 - 35 µm)* 3 µm (2 - 4 µm)* 2.8 N/m (0.5 - 9.5 N/m)* 75 kHz (45 - 115 kHz)*

* guaranteed range

Coating:
The PtIr5 coating is an approximately 25 nm thick double layer of chromium and platinum iridium5 on both sides of the cantilever. The tip side coating enhances the conductivity of the tip and allows electrical contacts. The detector side coating enhances the reflectivity of the laser beam by a factor of about 2 and prevents light from interfering within the cantilever. The coating process is optimized for stress compensation and wear resistance. The bending of the cantilever due to stress is less than 3.5% of the cantilever length.

**ScanAsyst® and Peak Force Tapping® are registered trademarks of Bruker Corporation.
*** Olympus® is a trademark of Olympus Corporation.

Apex Probes Ltd., 12th Floor, Ocean House, The Ring, Bracknell, RG12 1AX, Phone: +44 (0)1344 388016

© 2018 - Apex Probes | design by ISB