Order | Request an official quote (RFQ) |
---|
Order Code, Price (EUR/GBP) | Probes per set |
---|---|
qp-BioAC-CI-10 | 10 pcs |
€ 445.00 £ 392.00 |
![]() |
qp-BioAC-CI-20 | 20 pcs |
€ 786.00 £ 692.00 |
![]() |
qp-BioAC-CI-50 | 50 pcs |
€ 1745.00 £ 1536.00 |
![]() |
DANGER: One tiny amount of static electricity while you are handling these
probes will destroy the tip!
We highly recommend that you utilize an ESD
station and if you do not already have one, we have a mobile ESD station
for only £ ( EUR).
Considering the costs of these probes, this is a very wise investment.
NANOSENSORS qp-BioAC-CI AFM probes are based on NANOSENORS qp-BioAC probes.
For the qp-BioAC-CIM type the AFM tips have been rounded to a nominal tip radius of 30nm for Cell Imaging applications. This probe is dedicated to measurements on soft and life science samples only.
These probes feature three different rectangular cantilevers on one side of the support chip. The uniqprobe BioAC cantilevers unite fairly high resonance frequencies with low force constants.
The reflex gold coating deposited on the detector side of the cantilever covers only the free end above where the tip is located. Main advantages of the uniqprobe coating are considerably less cantilever bending and reduced drift particularly for measurements in liquid environments.
The NANOSENSORS uniqprobe combines the well-known features of the other NANOSENSORS AFM probe series such as high application versatility and compatibility with most commercial SPMs with the additional advantage of a strongly reduced dispersion of force constant and resonance frequency.
The unsurpassed uniformity of the mechanical characteristics of the uniqprobe series is particularly important for applications, where a large number of probes with known and near identical force constants or resonance frequencies are needed. The AFM probes of the uniqprobe series are especially adapted for molecular biology, biophysics and quantitative nano-mechanical studies.
The probe offers unique features:
shape | tip height | tip set back | tip radius | full cone angle | half cone angle | |
---|---|---|---|---|---|---|
Circular symmetric | 7 µm (5.5 - 8.5 µm)* | 5.5 - 8.5 µm* | ( | < 30 nm |
cant. | shape | length | width | thickness | force const. | res. freq. | probe base |
---|---|---|---|---|---|---|---|
1 Cantilever 1 | Beam | 40 µm (35 - 45 µm)* | 20 µm (18 - 22 µm)* | 400 nm (370 - 430 nm)* | 0.3 N/m (0.15 - 0.55 N/m)* | 90 kHz (65 - 115 kHz)* | |
2Cantilever 2 | Beam | 60 µm (55 - 65 µm)* | 25 µm (23 - 27 µm)* | 400 nm (370 - 430 nm)* | 0.1 N/m (0.06 - 0.18 N/m)* | 50 kHz (35 - 65 kHz)* | |
3Cantilever 3 | Beam | 80 µm (75 - 85 µm)* | 30 µm (28 - 32 µm)* | 400 nm (370 - 430 nm)* | 0.06 N/m (0.03 - 0.09 N/m)* | 30 kHz (24 - 36 kHz)* | |
* guaranteed range
**ScanAsyst® and Peak Force Tapping® are registered trademarks of Bruker Corporation.
*** Olympus® is a trademark of Olympus Corporation.
Apex Probes Ltd., 12th Floor, Ocean House, The Ring, Bracknell, RG12 1AX, Phone: +44 (0)1344 388016